    Product Details:

    Place of Origin: China
    Brand Name: Head-Power
    Certification: CE/ISO
    Model Number: HQD60

    Payment & Shipping Terms:

    Minimum Order Quantity: 1set
    Price: negotiation
    Packaging Details: Wooden case/carton case
    Delivery Time: 25~30days
    Payment Terms: TT, LC
    Supply Ability: 2000pcs per year
    Detailed Product Description
    Product Name: Heat Recovery Fresh Air Unit Application: Heat Recovery
    Fresh Air Flow: 6000 M3/h Exhaust Air Flow: 6000 M3/h
    Material: Galvanized Steel Sheet Heat Recovery: Plate Type Heat Recovery
    Heat Recovery Efficiency: 70% Power Supply: 380V/3PH/50Hz

    Mechanical Ventilation with Heat Recovery (MVHR) , Heat Recovery Ventilator 
     
    Specifications:
     

    Model

     

    HQD40

    HQD50HQD60HQD70

    Air Flow

    m3/h

    4000

    500060007000

    Power supply

     

    380V/3PH/50Hz

    Supply fan

    Type

     

    Centrifugal type

    Air volume

    m3/h

    4000

    500060007000

    External static 

    pressure

    Pa

    220

    220250250

    Motor power

    kW

    1.1

    1.11.51.5

    Drive method

     

    Belt drive

    Exhaust fan

    Type

     

    Centrifugal type

    Air volume

    m3/h

    4000

    500060007000

    External static 

    pressure

    Pa

    220

    220250250

    Motor power

    kW

    1.1

    1.11.51.5

    Drive method

     

    Driect drive

    Heat recovery

     

    Type

     

    Plate type heat recovery

    Material 

     

    Paper core/aluminium core

    Enthalpy efficiency

     

    65% / 68%

    65% / 68%65% / 68%65% / 68%
    Temp.efficiency 72% / 78%72% / 78%72% / 78%72% / 78%

    Noise level

    dB(A)

    52

    555858

    Dimensions(L*W*H)

    mm

    2300*1400*750

    2400*1400*7502800*1850*850

    Net weight

    kg

    210

    260280390

     
     
    Description:
    1. Galvanized steel sheet, painted or unpainted depends on requirement. 
    2. This heat recovery unit is simply for heat recovery and ventilation, combined with supply fan and                   motor, exhaust fan and motor, plate type heat recovery and frame work.
    3. Energy saving and improve indoor air quality: this fresh air unit can not only introduce fresh air to                improve indoor air quality, at the same time, it exchanges heat with exhaust air, which can precool for           preheat fresh air, save much energy.
    4. The heat recovery material is paper core or aluminium core. Paper core can recover full heat, while            aluminium core recover sensible heat only but it has longer lifespan and can bear higher temperature.
    5. Rectangular type heat recovery or rhombus type heat recovery, cross flow, high efficiency;
    6. Washable nylon prefilter is installed at fresh air intake.  Other types of filter is optional.
    7. Cooling coil or heating coil is optional to be heat recovery AHU.
    8. Air volume: 1000 m3/h ~10000 m3/h. Bigger model also could be customized.
    9. Standard power supply: 380V/3PH/50Hz, others like 440V/3PH/60Hz, 220V/3PH/60Hz available.
     Mechanical Ventilation Fresh Air Heat Recovery Unit , Energy Saving MVHR Unit
     
    Advantages:
     
    1. Heat and energy heat recovery, saving energy for building consumption. 
    2. Introduce fresh air, exhaust polluted air, improvde indoor air quality;
    3. Wide volume range, meet different requirements of industrial, commercial and residential building;
    4. Good quality heat exchange device, high efficiency and long lifespan. 
    5. Easy for maintainance and operation, low cost. 
     
    Applications:
    1. Commercial buildings: Star hotels, restaurants, office buildings, schools, supermarkets, shopping mall, entertainment centers,theaters,etc
    2. Industrial field: Electronic factory,pharmaceutical factory, precision instrument factory,petrochemical factory,tobacco factory, cooling for production process, etc.
    3. Public places: Airports, stations, exhibition halls, stadiums, museums, convention centers, church,etc
    Mechanical Ventilation Fresh Air Heat Recovery Unit , Energy Saving MVHR UnitMechanical Ventilation Fresh Air Heat Recovery Unit , Energy Saving MVHR Unit
       
    Mechanical Ventilation Fresh Air Heat Recovery Unit , Energy Saving MVHR Unit
     

    Contact Details
    Lingdo Industrial Limited

    Contact Person: Ms. Cathy Peng

    Send your inquiry directly to us (0 / 3000)

    Other Products